The compact 1U form factor design, ultra-low ripple and high voltage accuracy of ±0.02% F.S. mark ZETA programmable DC power supply as the ideal testing instrument for laboratory application where precision and footprint are among the most valued factors. ZETA supports four primary operating modes including CV, CC, CVCP, and CCCP along with custom waveform programming through advanced software or host PC. The chassis comes with full-screen display and dual-shuttle rotary knobs for improved user-interaction when operating on an in-lab test bench. Single unit of 1U chassis delivers up to 5kW maximum per while further allowing master-slave series/parallel capabilities of up to 100 units.
Detailed installation, operation procedures, and safety information for engineers.
| Model | Power (kVA) | Voltage Range (V) | Current Range (A) | Voltage Ripple RMS (mV) (5Hz-1MHz) |
Rise Time (ms) (Programmed Response) |
Fall Time @ Full Load (ms) (Programmed Response) |
Current Ripple RMS @ Rated Voltage (mA) |
Input Voltage (V) |
|---|---|---|---|---|---|---|---|---|
| ZD1.7-020 | 1.7 | 0~20 | 0~200 | 10 | 30 | 50 | 300 | 220 |
| ZD1.7-040 | 1.7 | 0~40 | 0~125 | 12 | 30 | 80 | 75 | 220 |
| ZD1.7-060 | 1.7 | 0~60 | 0~85 | 12 | 50 | 80 | 50 | 220 |
| ZD1.7-100 | 1.7 | 0~100 | 0~50 | 15 | 50 | 100 | 23 | 220 |
| ZD1.7-150 | 1.7 | 0~150 | 0~34 | 20 | 50 | 100 | 23 | 220 |
| ZD1.7-350 | 1.7 | 0~350 | 0~15 | 60 | 50 | 100 | 7.5 | 220 |
| ZD1.7-750 | 1.7 | 0~750 | 0~7 | 100 | 100 | 200 | 4 | 220 |
| ZD3.0-020 | 3 | 0~20 | 0~200 | 10 | 30 | 50 | 300 | 220 |
| ZD3.0-020H | 3 | 0~20 | 0~200 | 10 | 30 | 50 | 300 | 220 |
| ZD3.0-030 | 3 | 0~30 | 0~170 | 12 | 30 | 80 | 150 | 220 |
| ZD3.0-040 | 3 | 0~40 | 0~125 | 12 | 30 | 80 | 75 | 220 |
| ZD3.0-040H | 3 | 0~40 | 0~125 | 12 | 30 | 80 | 75 | 220 |
| ZD3.0-060 | 3 | 0~60 | 0~85 | 12 | 50 | 80 | 50 | 220 |
| ZD3.0-100 | 3 | 0~100 | 0~50 | 15 | 50 | 100 | 23 | 220 |
| ZD3.0-150 | 3 | 0~150 | 0~34 | 20 | 50 | 100 | 23 | 220 |
| ZD3.0-2K0 | 3 | 0~2000 | 0~1.5 | 300 | 100 | 200 | 4 | 220 |
| ZD3.0-350 | 3 | 0~350 | 0~15 | 60 | 50 | 100 | 7.5 | 220 |
| ZD3.0-750 | 3 | 0~750 | 0~7 | 100 | 100 | 200 | 4 | 220 |
| ZD3.6-020 | 3.6 | 0~20 | 0~200 | 10 | 30 | 50 | 300 | 380 |
| ZD3.6-030 | 3.6 | 0~30 | 0~170 | 12 | 30 | 80 | 150 | 380 |
| ZD3.6-040 | 3.6 | 0~40 | 0~125 | 12 | 30 | 80 | 75 | 380 |
| ZD3.6-060 | 3.6 | 0~60 | 0~85 | 12 | 50 | 80 | 50 | 380 |
| ZD3.6-100 | 3.6 | 0~100 | 0~50 | 15 | 50 | 100 | 23 | 380 |
| ZD3.6-150 | 3.6 | 0~150 | 0~34 | 20 | 50 | 100 | 23 | 380 |
| ZD3.6-350 | 3.6 | 0~350 | 0~15 | 60 | 50 | 100 | 7.5 | 380 |
| ZD3.6-750 | 3.6 | 0~750 | 0~7 | 100 | 100 | 200 | 4 | 380 |
| ZD5.0-030 | 5 | 0~30 | 0~170 | 12 | 30 | 80 | 150 | 380 |
| ZD5.0-100 | 5 | 0~100 | 0~50 | 15 | 50 | 100 | 23 | 380 |
| ZD5.0-150 | 5 | 0~150 | 0~34 | 20 | 50 | 100 | 23 | 380 |
| ZD5.0-350 | 5 | 0~350 | 0~15 | 60 | 50 | 100 | 7.5 | 380 |
| ZD5.0-750 | 5 | 0~750 | 0~7 | 100 | 100 | 200 | 4 | 380 |
ZETA Series High-Precision Laboratory Programmable DC Power Supply achieves an ultra-high power density of up to 5kW within a compact 1U chassis. With output capabilities reaching up to 2000V and 200A, this series is explicitly designed for demanding industrial applications and cutting-edge scientific research, delivering an impeccable testing experience.
A pure power output is the cornerstone of authentic test data. The PDC series employs a rigorous hardware architecture and high-quality filtering components to achieve ultra-low ripple and noise performance. Its voltage ripple (RMS) is as low as 10mV, and its current ripple (RMS) reaches an impressive 4mA. Whether driving highly sensitive semiconductor devices or powering precision medical equipment for testing, it provides smooth, pure, and stable direct current comparable to a battery.
ZETA series features exceptional setting and readback resolution, with voltage and current output accuracy reaching up to ±0.02% F.S. (two ten-thousandths of the full scale). In those accuracy-demanding fields with zero tolerance for error, such as aerospace, satellite testing, and scientific particle accelerators, ZETA provides precision test data with absolute confidence.
ZETA addresses the challenges of non-linear load testing with a comprehensive range of operating mode options.
In addition to traditional Constant Voltage (CV) and Constant Current (CC) modes, it features specialized Constant Voltage Constant Power (CVCP) and Constant Current Constant Power (CCCP) modes to prevent damage to the Device Under Test (DUT) under extreme conditions.
Optional software and control integration is available to upscale ZETA into a battery simulator for new energy and motor drive testing application, with program-controlled Internal Resistance profiles for replicating the charging and discharging characteristics of a real battery.
A standalone chassis is just the initial setup for your test-bench as we may understand. Test engineer can scale up the test bench until a master-slave series or parallel connection system with up to 100 units of ZETA aligned. The system automatically handles current sharing or voltage superposition without the need for tedious external calibration or code rewriting. Apart from current or voltage upscaling, the 1U standard chassis and form factor design allows ZETA to be integrated as well into an ATE for building an automated testing system.
ZETA integrates isolated analogue control (5V/10V via the REMOTE port) with high-speed digital waveform programming featuring an ultra-fast 1ms resolution. Setting up of automated testing sequences can follow up to 200-steps with 10 stored profiles available, along with 999-step custom waveforms.
The system further provides real-time voltage and current monitoring to ensure effortless PLC and ATE integration. By combining the precision of analogue adjustment with the ultimate flexibility of digital waveforms in a single unit, it serves as the definitive solution for automated testing, stress cycling, and real-world power simulation.
Note: The technical parameters contained within the below specification tables are subject to updates and modifications without notification in advance. For more detailed technical information please contact our sales and technical support team.
| Maximum Input Current at 100% Load | 15A@220Vac 9.2A@380Vac |
|---|---|
| Input Voltage/Frequency | 220V Model: 185~265Vac; 47~63Hz 380V Model: 304~460Vac; 47~63Hz |
| Inrush Current | 30A@220Vac 15A@380Vac |
| Power Factor (Typical) | 0.97 |
| Efficiency (%) | 91@20V~350V Model 92@350V~2000V Model |
| Programming Accuracy | ±0.02% of rated voltage |
|---|---|
| Display Accuracy | ±0.02% of rated voltage |
| Source Regulation | ±0.01% of rated voltage |
| Load Regulation | 0.01% of rated output voltage |
| Temperature Coefficient | 20PPM/°C of rated output voltage (after 30 minutes of power-on) |
| Transient Response Time |
When the load current changes between 10% to 90% of the rated output current, the time required for the output voltage to recover to within 0.5% of the rated output voltage:
|
| Programming Accuracy |
±0.1% of rated current (Standard) ±0.05% of rated current (High-Performance Version) |
|---|---|
| Display Accuracy |
±0.1% of rated current (Standard) ±0.05% of rated current (High-Performance Version) |
| Source Regulation | ±0.01% of rated current |
| Load Regulation |
±0.1% of rated output current (Standard) ±0.05% of rated output current (High-Performance Version) |
| Temperature Coefficient |
20PPM/°C of rated output current (Standard) 5PPM/°C of rated output current (High-Performance Version) (after 30 minutes of power-on) |
| Programming Accuracy | ±0.1% of rated current (Standard) |
|---|---|
| Programming Resolution | 0.1W |
| Programming Accuracy (Power) | ±0.1% of rated power |
| Display Resolution | 1W |
| Display Accuracy | ±0.1% of rated power |
| Rated Impedance | ±0.1% of rated current (Standard) |
|---|---|
| Setting Resolution | 0.1mΩ |
| Setting Accuracy | ±1% of rated impedance |
| Programming Steps | 200 steps |
|---|---|
| Cycle Count | 999,999 |
| Minimum Programming Step Time | 1ms |
| Operation Modes | Load, End, Trigger |
| Supported Modes | List, Wave |
| Voltage Programming of Voltage Output |
Range: 0~100% (0~5V or 0~10V, user-selectable) Accuracy & Linearity: ±0.1% of rated output voltage |
|---|---|
| Voltage Programming of Current Output |
Range: 0~100% (0~5V or 0~10V, user-selectable) Accuracy & Linearity: ±0.1% of rated output voltage |
| Resistance Programming of Voltage Output |
Range: 0~100% (0~5/10 kΩ full scale, user-selectable) Accuracy & Linearity: ±0.5% of rated output voltage |
| Resistance Programming of Current Output |
Range: 0~100% (0~5/10 kΩ full scale, user-selectable) Accuracy & Linearity: ±0.5% of rated output voltage |
| Output Voltage Monitoring |
Range: 0~5V or 0~10V (user-selectable) Accuracy: ±0.1% F.S. |
| Output Current Monitoring |
Range: 0~5V or 0~10V (user-selectable) Accuracy: ±0.1% F.S. |
| Voltage Programming of Voltage Output |
|
|---|---|
| CV/CC Signal (Status) |
|
| CV/CC Signal (Control) |
|
| LOCAL/REMOTE Status Monitoring |
|
| ENABLE/DISABLE Signal |
|
| INTERLOCK (ILC) Control |
|
| Programming Signal |
|
| TRIGGER IN/TRIGGER OUT Signal |
|
ActionPower India is a regional network of Xi'an ActionPower Electric Co., Ltd., represented by Tangent Test Technologies in India for supporting business development and technical services for our regional clientele in the field of power testing. With 5 regional locations in India.
With 30 years of experience with power electronics and testing solutions, further backed by 295+ patents that enforce our technological advancement, we are ready to uncomplicate your challenges of industrial regulation compliance with IEC, IEEE, UL and India local grid code standards.