ZETA laboratory programmable DC power supply

ZETA High-Precision Laboratory DC Programmable Power Supply

1U Form Factor, ±0.02% F.S. Laboratory-Purposed Accuracy and Precision, ATE-Integration Options


The compact 1U form factor design, ultra-low ripple and high voltage accuracy of ±0.02% F.S. mark ZETA programmable DC power supply as the ideal testing instrument for laboratory application where precision and footprint are among the most valued factors. ZETA supports four primary operating modes including CV, CC, CVCP, and CCCP along with custom waveform programming through advanced software or host PC. The chassis comes with full-screen display and dual-shuttle rotary knobs for improved user-interaction when operating on an in-lab test bench. Single unit of 1U chassis delivers up to 5kW maximum per while further allowing master-slave series/parallel capabilities of up to 100 units.

User Manual

【User Manual】ZETA Series Laboratory DC Programmable Power Supply

Detailed installation, operation procedures, and safety information for engineers.

Model Options

Model Power (kVA) Voltage Range (V) Current Range (A) Voltage Ripple RMS (mV)
(5Hz-1MHz)
Rise Time (ms)
(Programmed Response)
Fall Time @ Full Load (ms)
(Programmed Response)
Current Ripple RMS
@ Rated Voltage (mA)
Input Voltage (V)
ZD1.7-020 1.70~200~200103050300220
ZD1.7-040 1.70~400~12512308075220
ZD1.7-060 1.70~600~8512508050220
ZD1.7-100 1.70~1000~50155010023220
ZD1.7-150 1.70~1500~34205010023220
ZD1.7-350 1.70~3500~1560501007.5220
ZD1.7-750 1.70~7500~71001002004220
ZD3.0-020 30~200~200103050300220
ZD3.0-020H 30~200~200103050300220
ZD3.0-030 30~300~170123080150220
ZD3.0-040 30~400~12512308075220
ZD3.0-040H 30~400~12512308075220
ZD3.0-060 30~600~8512508050220
ZD3.0-100 30~1000~50155010023220
ZD3.0-150 30~1500~34205010023220
ZD3.0-2K0 30~20000~1.53001002004220
ZD3.0-350 30~3500~1560501007.5220
ZD3.0-750 30~7500~71001002004220
ZD3.6-020 3.60~200~200103050300380
ZD3.6-030 3.60~300~170123080150380
ZD3.6-040 3.60~400~12512308075380
ZD3.6-060 3.60~600~8512508050380
ZD3.6-100 3.60~1000~50155010023380
ZD3.6-150 3.60~1500~34205010023380
ZD3.6-350 3.60~3500~1560501007.5380
ZD3.6-750 3.60~7500~71001002004380
ZD5.0-030 50~300~170123080150380
ZD5.0-100 50~1000~50155010023380
ZD5.0-150 50~1500~34205010023380
ZD5.0-350 50~3500~1560501007.5380
ZD5.0-750 50~7500~71001002004380

Technical Features

ZETA Series High-Precision Laboratory Programmable DC Power Supply achieves an ultra-high power density of up to 5kW within a compact 1U chassis. With output capabilities reaching up to 2000V and 200A, this series is explicitly designed for demanding industrial applications and cutting-edge scientific research, delivering an impeccable testing experience.


Stable Output with Low-Ripple Components

A pure power output is the cornerstone of authentic test data. The PDC series employs a rigorous hardware architecture and high-quality filtering components to achieve ultra-low ripple and noise performance. Its voltage ripple (RMS) is as low as 10mV, and its current ripple (RMS) reaches an impressive 4mA. Whether driving highly sensitive semiconductor devices or powering precision medical equipment for testing, it provides smooth, pure, and stable direct current comparable to a battery.


Ultra High Precision and Accuracy for Laboratory Test Application

ZETA series features exceptional setting and readback resolution, with voltage and current output accuracy reaching up to ±0.02% F.S. (two ten-thousandths of the full scale). In those accuracy-demanding fields with zero tolerance for error, such as aerospace, satellite testing, and scientific particle accelerators, ZETA provides precision test data with absolute confidence.

ultra low ripple of ZETA programmable power supply

Versatile Operation Modes of CC, CV, CVCP and CPCV

ZETA addresses the challenges of non-linear load testing with a comprehensive range of operating mode options.

 

In addition to traditional Constant Voltage (CV) and Constant Current (CC) modes, it features specialized Constant Voltage Constant Power (CVCP) and Constant Current Constant Power (CCCP) modes to prevent damage to the Device Under Test (DUT) under extreme conditions.

Optional software and control integration is available to upscale ZETA into a battery simulator for new energy and motor drive testing application, with program-controlled Internal Resistance profiles for replicating the charging and discharging characteristics of a real battery.

dynamic mode CC CV CR CP operation of ZETA DC power supply

master-slave parallation series connection ZETA power

Automatic Master-Slave Series/Parallel Operation

A standalone chassis is just the initial setup for your test-bench as we may understand. Test engineer can scale up the test bench until a master-slave series or parallel connection system with up to 100 units of ZETA aligned. The system automatically handles current sharing or voltage superposition without the need for tedious external calibration or code rewriting. Apart from current or voltage upscaling, the 1U standard chassis and form factor design allows ZETA to be integrated as well into an ATE for building an automated testing system.


Advanced Programmable Control & Waveform Generation

ZETA integrates isolated analogue control (5V/10V via the REMOTE port) with high-speed digital waveform programming featuring an ultra-fast 1ms resolution. Setting up of automated testing sequences can follow up to 200-steps with 10 stored profiles available, along with 999-step custom waveforms.

The system further provides real-time voltage and current monitoring to ensure effortless PLC and ATE integration. By combining the precision of analogue adjustment with the ultimate flexibility of digital waveforms in a single unit, it serves as the definitive solution for automated testing, stress cycling, and real-world power simulation.

automated waveform generation ZETA programmable DC power supply

Technical Specifications

Note: The technical parameters contained within the below specification tables are subject to updates and modifications without notification in advance. For more detailed technical information please contact our sales and technical support team.

INPUT PARAMETERS

Maximum Input Current at 100% Load 15A@220Vac
9.2A@380Vac
Input Voltage/Frequency 220V Model: 185~265Vac; 47~63Hz
380V Model: 304~460Vac; 47~63Hz
Inrush Current 30A@220Vac
15A@380Vac
Power Factor (Typical) 0.97
Efficiency (%) 91@20V~350V Model
92@350V~2000V Model

CONSTANT VOLTAGE MODE

Programming Accuracy ±0.02% of rated voltage
Display Accuracy ±0.02% of rated voltage
Source Regulation ±0.01% of rated voltage
Load Regulation 0.01% of rated output voltage
Temperature Coefficient 20PPM/°C of rated output voltage (after 30 minutes of power-on)
Transient Response Time When the load current changes between 10% to 90% of the rated output current, the time required for the output voltage to recover to within 0.5% of the rated output voltage:
  • Models ≤100V: ≤1ms
  • Models >100V: ≤2ms

CONSTANT CURRENT MODE

Programming Accuracy ±0.1% of rated current (Standard)
±0.05% of rated current (High-Performance Version)
Display Accuracy ±0.1% of rated current (Standard)
±0.05% of rated current (High-Performance Version)
Source Regulation ±0.01% of rated current
Load Regulation ±0.1% of rated output current (Standard)
±0.05% of rated output current (High-Performance Version)
Temperature Coefficient 20PPM/°C of rated output current (Standard)
5PPM/°C of rated output current (High-Performance Version) (after 30 minutes of power-on)

CONSTANT POWER MODE

Programming Accuracy ±0.1% of rated current (Standard)
Programming Resolution 0.1W
Programming Accuracy (Power) ±0.1% of rated power
Display Resolution 1W
Display Accuracy ±0.1% of rated power

INTERNAL RESISTANCE MODE

Rated Impedance ±0.1% of rated current (Standard)
Setting Resolution 0.1mΩ
Setting Accuracy ±1% of rated impedance

PROGRAMMING MODE

Programming Steps 200 steps
Cycle Count 999,999
Minimum Programming Step Time 1ms
Operation Modes Load, End, Trigger
Supported Modes List, Wave

ANALOGUE PROGRAMMING & MONITORING (ISOLATED)

Voltage Programming of Voltage Output Range: 0~100% (0~5V or 0~10V, user-selectable)
Accuracy & Linearity: ±0.1% of rated output voltage
Voltage Programming of Current Output Range: 0~100% (0~5V or 0~10V, user-selectable)
Accuracy & Linearity: ±0.1% of rated output voltage
Resistance Programming of Voltage Output Range: 0~100% (0~5/10 kΩ full scale, user-selectable)
Accuracy & Linearity: ±0.5% of rated output voltage
Resistance Programming of Current Output Range: 0~100% (0~5/10 kΩ full scale, user-selectable)
Accuracy & Linearity: ±0.5% of rated output voltage
Output Voltage Monitoring Range: 0~5V or 0~10V (user-selectable)
Accuracy: ±0.1% F.S.
Output Current Monitoring Range: 0~5V or 0~10V (user-selectable)
Accuracy: ±0.1% F.S.

SIGNALS & CONTROLS (ISOLATED FROM OUTPUT)

Voltage Programming of Voltage Output
  • Range: 0~100% (0~5V or 0~10V, user-selectable)
  • Output Monitoring: Open-collector
  • Output ON: Conducting | Output OFF: Open
  • Max Voltage: 30V | Max Current: 10mA
CV/CC Signal (Status)
  • Monitoring: Open-collector
  • CC Mode: Conducting | CV Mode: Open
  • Max Voltage: 30V | Max Current: 10mA
CV/CC Signal (Control)
  • Enable/Disable via Electrical Signal or Dry Contact
  • External Control: 0~0.6V or Short-Circuit
  • Local Control: 2~30V or Open-Circuit
LOCAL/REMOTE Status Monitoring
  • Analogue Control Monitoring Signal: Open-collector
  • External Control: Conducting | Local Control: Open
  • Max Voltage: 30V | Max Sink Current: 10mA
ENABLE/DISABLE Signal
  • Enable/Disable PS Output via Electrical Signal or Dry Contact
  • Enable: 0~0.6V or Short-Circuit | Disable: 2~30V or Open-Circuit
  • User-Selectable Logic
INTERLOCK (ILC) Control
  • Enable/Disable PS Output via Electrical Signal or Dry Contact
  • Enable: 0~0.6V or Short-Circuit | Disable: 2~30V or Open-Circuit
Programming Signal
  • Two Open-Drain Programmable Signals
  • Max Voltage: 25V
  • Max Sink Current: 100mA (Clamped by 27V Zener Diode)
TRIGGER IN/TRIGGER OUT Signal
  • Max Low-Level Input Voltage = 0.8V
  • Min High-Level Input Voltage = 2.5V | Max High-Level Input = 5V
  • Rising Edge Trigger: Pulse Width (Tw) ≥ 10μs (Min)
  • Rise/Fall Time (Tr/Tf) ≤ 1μs (Max)
  • Minimum Delay Between Pulses: 1ms